  • c36-1.jpg
  • c36.jpg

WXZD Series Pipeline Thrust-free Rotary Compensator

Under the action of the spring, the sealing packing is always in a compressed state in a special structure, so that the liquid or gas medium in the pipeline has no leakage; the sealing packing is well selected, so that the product has a longer service life.
Under the action of the spring, the sealing packing is always in a compressed state in a special structure, so that the liquid or gas medium in the pipeline has no leakage; the sealing packing is well selected, so that the product has a longer service life.

Keyword: WXZD Series Pipeline Thrust-free Rotary Compensator

Product Consulting:

Product Description

Under the action of the spring, the sealing packing is always in a compressed state in a special structure, so that the liquid or gas medium in the pipeline has no leakage; the sealing packing is well selected, so that the product has a longer service life.

Technical parameters

Nominal diameter
DN
Piping outer diameter
D
telescopic compensator
△Lmax
Mounting outer diameter
D outside
Installation length
L
Tension bolt in 0.16MPa table
Friction force under pressure (Kg)
Theoretical weight
Kg
25 32 -50 100=150 100 750 32 13.5
32 38 -60 90=150 120 840 36 15.2
36 42 -60 140=200 135 840 40 16.30
39 45 -60 140=200 135 840 44 19.40
50 57 -60 140=200 150 840 51 20.10
55 60 -60 140=200 150 840 59 23.35
65 73 -80 120=200 160 840 63 25.01
70 76 -80 120=200 160 840 69 26.43
80 89 -80 120=200 185 840 77 37.55
100 108 -100 150=250 220 975 150 42.14
125 133 -100 150=250 235 850 230 55.71
150 159 -100 150=250 260 850 349 59.95
175 194 -100 150=250 310 850 475 94.78
200 219 -100 200=300 335 975 620 120.11
225 245 -100 200=300 340 440 751 178.33
250 273 -100 200=300 390 975 974 209.45
300 325 -140 210=350 426 1080 1401 260.15
350 377 -140 210=350 500 1080 1919 324.76
400 920 -140 260=400 565 1170 2502 381.33
450 478 -140 260=400 615 1170 3170 391.75
500 529 -140 260=400 670 1170 3900 429.44
600 630 -180 270=450 780 1280 5620 551.77
700 720 -180 270=450 895 1280 7670 596.74
800 820 -220 280=500 1010 1380 8520 635.21
900 920 -220 280=500 1110 1380 9620 716.52
1000 1020 -220 280=500 1220 1380 10500 781.73

 

DN 25 32 36 40 50 57 65 70 80 100 125 150 175 200 225 250 300 350 400 450 500 600 700
D 31 37 41 44 56 59 72 75 87 106 131 157 192 217 243 270| 322 373 422 476 525 626 720
B 40 40 40 40 40 40 40 40 40 70 70 70 70 70 70 70 85 85 85 85 85 85 85

Use Installation

1. When the automatic compensator of the pipeline is welded with the pipeline, the joint of the pipeline shall be beveled. After welding, flaw detection shall be carried out according to the requirements of the pressure vessel, and hydraulic pressure test shall be carried out. During the test, the sealing and pressing parts shall be adjusted to no leakage. The stress of each part shall be consistent, and torque wrench is best used.

2. The sliding bracket and fixed bracket shall be installed according to the design. In order to ensure that the pipeline has no lateral displacement and expands and contracts along the axial direction, the compensator shall be installed near the fixed bracket, and the guide bracket shall be set on the movable side. The fixed bracket must be installed at the turning point of the pipeline.

3. The thermal insulation and waterproof structure of the compensator can be the same as that of the pipeline, but it can not produce binding force on the telescopic pipe.

4. If the inner tube is accidentally pulled out during installation, it should be reassembled and tested before installation on the pipeline.

5. The compensator can be installed according to the maximum installation length L under various temperatures without pre-pulling or pre-pressing. If the loose length of the casing is misaligned during installation, the casing can be pushed or pulled out, and then installed after calibration and compression.

6. See the following sketch for general installation method:

 